![]() This anaesthetic has more than one structural configuration. An example low energy conformer is shown. Surface View:
On Off
Surface view shows the electrostatic potential of the conformer mapped onto
the solvent excluded surface, based on a probe of radius 1.4Å.
Regions of negative potential are shown in red, positive in blue.
|
|
In Vivo Activity Data | ||
Immobility: MAC Human (atm) | 0.02 | Bourne JG. Nitrous Oxide in Dentistry. London: Lloyd-Luke, 1960 |
---|---|---|
Physical Properties | ||
Blood / Gas Partition Coeff. at 37°C | 2 | Steward A, Allott PR, Cowles AL & Mapleson WW. Br J Anaesth 1973;45:282-93 |
Water / Gas Partition Coeff. at 37°C | 1.2 | Steward A, Allott PR, Cowles AL & Mapleson WW. Br J Anaesth 1973;45:282-93 |
Calculated Molecular Properties | ||
van der Waals Volume | 57 Å3 | |
van der Waals Surface Area | 89 Å2 | |
Solvent Accessible Volume | 262 Å3 | (based on a 1.4Å probe) |
Solvent Accessible Surface Area | 207 Å2 | (based on a 1.4Å probe) |
All values are mean ± SD, except
data labelled with † which are mean ± SEM.
Use of this web site assumes acceptance of our
Copyright & Licence conditions.
Database Version: 1.09.9 Last Updated: 21st February 2014